1010 kVA Diesel Generator on Rent

Institutional campuses where downtime is a compliance event — server halls, dealing rooms, security systems.

Rating1010 kVA / 808 kWe
ModelC1010D5P
Emission normMoEFCC >800 kW
EngineKTA 38 G5

What it powers

Institutional campuses where downtime is a compliance event — server halls, dealing rooms, security systems.

High-rise infrastructure: fire pumps, staircase pressurisation, lifts and house power at once.

Synchronised in N+1 banks for loads that must never see a dark second.

Size for starting current, not running load — direct-on-line motor starting draws six to seven times full-load current. Send us your load list and we size it free of charge.

Specification

Genset

Model
C1010D5P
Prime rating
1010 kVA / 808 kWe
Voltage · frequency
415 V · 50 Hz
Phases · power factor
3-phase · 0.8 PF
Speed
1,500 RPM
Emission norm
MoEFCC >800 kW
Controller
PCC3.3 with AMF

Engine

Make · model
Cummins KTA 38 G5
Certified power
1,180 HP
Cylinders
12, 'Vee'
Bore × stroke
159 × 159 mm
Displacement
37.8 L
Compression ratio
13.9:1
Aspiration
Turbocharged-Aftercooled
Cooling
Water cooled (Radiator or Heat exchanger)
Fuel
High Speed Diesel
Starting system
Starting motor – Electric, Battery charging alternator
Coolant capacity
260 L

Alternator

Make
Stamford
Frame
HC6Y
Enclosure · insulation
IP 23 · Class H
Voltage regulation
+ 0.5%
Winding pitch
2 / 3 Pitch

Open genset dimensions

Dimensions (L × W × H)
4,526 × 2,140 × 2,721 mm
Wet weight
9,538 kg
Fuel tank
990 L

Fuel consumption

At 75% load
153.3 L/hr
At 100% load
203.8 L/hr

Source: Cummins specification sheet for the C1010D5P · rev. 07-2018. Diesel SG 0.85 per IS:1460; tolerance +5%. Actual consumption varies with load profile and site conditions.

Transcribed from the Cummins India specification sheet for the C1010D5P. Ratings are prime power per ISO 8528; site conditions can derate output — confirm against your load list. Dimensions are for the open set; acoustic treatment is engineered per site.

Rental, the way we run it

Rates move with tenure, site and season — so we quote same-day, not never.

  • Set delivered, positioned and commissioned — acoustic treatment engineered per site
  • Scheduled B-check maintenance every 250–300 running hours, included
  • 4–6-hour breakdown response on live contracts

1010 kVA, answered

Frequently asked questions

What does a 1010 kVA generator run?

A 1010 kVA (808 kW) set serves institutional campuses — server halls, dealing rooms, security infrastructure — and high-rise central services. It is a signature rating of our fleet, deployed in synchronised banks where a dark second is a reportable event.

Is the 1010 kVA set CPCB IV+ compliant?

CPCB IV+ applies to gensets with engines up to 800 kW — the C1010D5P’s engine is above that threshold, so it is governed by the MoEFCC’s separate emission standards for >800 kW diesel engines, not CPCB IV+. It is fully legal to deploy on rental; stack height, siting and consent conditions are engineered into the deployment, and we advise on state-specific requirements where they apply.

What does it take to place a 1010 kVA set on site?

This is trailer-and-crane territory — the C1010D5P’s open set runs 4.5 m and roughly 9,538 kg wet — so we plan the crane day, cable runs, acoustic treatment and (where applicable) synchronisation panels as part of the deployment, not as surprises. Site survey, delivery, commissioning and scheduled B-checks are all included.

Related

Reply within 4 working hours. Engineered offer within 24 hours.