DG Rental · 500 kVA

500 kVA Diesel Generator on Rent

A large factory's full production load run as prime power, day after day, outage after outage.

Rating500 kVA / 400 kWe
ModelCI 500D5P
Emission normCPCB IV+
Noise75 dBA @ 1 m

What it powers

A large factory's full production load run as prime power, day after day, outage after outage.

An IT floor plus precision-cooled server rooms carried through utility failures.

A construction project's tower cranes, batching plant and site utilities on a single set.

Size for starting current, not running load — direct-on-line motor starting draws six to seven times full-load current. Send us your load list and we size it free of charge.

Specification

Genset

Model
CI 500D5P
Prime rating
500 kVA / 400 kWe
Full-load current
695.6 A
Voltage · frequency
415 V · 50 Hz
Phases · power factor
3-phase · 0.8 PF
Speed
1,500 RPM
Emission norm
CPCB IV+
Controller
PS0602 with AMF

Engine

Make · model
Cummins QSM15-G1
Certified power
594 HP
Cylinders
6, In-line
Bore × stroke
135 × 169 mm
Displacement
14.5 L
Compression ratio
23:1
Aspiration
Turbocharged, Charge Air Cooled
Cooling
Liquid Cooled (EG Compleat 50:50)
Fuel
High Speed Diesel
DEF
AUS 32 (Premix) as per ISO 22241
Starting system
24 V DC Electrical
Lube oil spec
CK4
Coolant capacity
67 L
Performance class
ISO 8528-5 G2

Alternator

Make
STAMFORD (CGT)
Frame
HCI544D
Enclosure · insulation
IP 23 · Class H
Voltage regulation
±1%
Winding pitch
2/3

Acoustic enclosure

Dimensions (L × W × H)
5,300 × 1,900 × 2,490 mm
Wet weight
5,915 kg
Fuel tank
745 L
DEF tank
87 L
Noise level
75 dBA (1 m, 75% load, free-field (MoEF/CPCB))

Transcribed from the Cummins India specification sheet for the CI 500D5P. Ratings are prime power per ISO 8528; site conditions can derate output — confirm against your load list.

Rental, the way we run it

Rates move with tenure, site and season — so we quote same-day, not never.

  • Acoustic-enclosed set, delivered and commissioned
  • Scheduled B-check maintenance every 250–300 running hours, included
  • 4–6-hour breakdown response on live contracts

500 kVA, answered

Frequently asked questions

What does a 500 kVA generator run?

A 500 kVA (400 kW) set is the workhorse of large-site rental: a factory’s full production load as prime power, an IT floor with precision cooling, or a construction project’s cranes and batching plant. It is the single most quoted rating in the Indian rental market — which is exactly why sizing against your actual load list, not the market default, matters.

Does the 500 kVA CPCB IV+ set use DEF (AdBlue)?

Yes. The CI 500D5P meets CPCB IV+ with SCR after-treatment using AUS 32 (DEF) per ISO 22241, fed from a 87 litre on-board tank. On rentals we manage DEF top-ups as part of scheduled service; on owned sets we train your operator on consumption and quality — wrong or diluted DEF is a warrantable failure.

What does it take to place a 500 kVA set on site?

This is trailer-and-crane territory — the CI 500D5P’s enclosure runs 5.3 m and roughly 5,915 kg wet — so we plan the crane day, cable runs and (where applicable) synchronisation panels as part of the deployment, not as surprises. Site survey, delivery, commissioning and scheduled B-checks are all included.